Mi-T-M AG2 Series Stationary Air Compressor / Generator Combination Units
Mi-T-M AG2 Series Stationary Air Compressor / Generator Combination Units are the definitive heavy-duty power plants for commercial service trucks, emergency mechanics, and remote field workstations. Engineered to save substantial bed space and reduce vehicle weight, these multi-tasking machines pack a high-output two-stage cast-iron compressor pump and a high-capacity 3500-watt generator onto a single stationary frame.
Driven by premium, commercial-grade gas engines—or a rugged diesel option—this series delivers a relentless 15.7 CFM @ 175 PSI alongside clean, brushless electrical energy to power high-torque impact wrenches, field welders, and work lights simultaneously.
Understanding the 3 Stationary Footprints
The stationary lineup is broken down into three distinct structural footprints to integrate perfectly with your service truck body or mechanics skid. Models ending in “E” indicate factory Electric Start (recoil backup included on gas engines).
- The 8-Gallon Twin-Tank Stationary Series
Features a compact, low-profile wheelbarrow-style layout but replaces the wheel and handles with solid, stationary vibration-dampening feet for permanent bolting.
- Honda GX390: AG2-SH13-08M1 (Recoil) | AG2-SH13-08M1E (Electric)
- Kohler CH440: AG2-SK14-08M1 (Recoil) | AG2-SK14-08M1E (Electric)
- Mi-T-M 420cc: AG2-SM14-08M1 (Recoil) | AG2-SM14-08M1E (Electric)
- Vanguard 400: AG2-PV14-08M1 (Recoil) | AG2-SV14-08M1E (Electric)
- The Space-Saving Base Mount (BM) Skid Series (Suffix “-B / -BE”)
Designed for space-critical truck beds or direct integration into existing mechanical layouts, these specialized skid units completely omit the built-in air receiver tank, routing compressed air straight to an external storage tank.
- Honda GX390: AG2-SH13-B (Recoil) | AG2-SH13-BE (Electric)
- Kohler CH440: AG2-SK14-B (Recoil) | AG2-SK14-BE (Electric)
- Mi-T-M 420cc: AG2-SM14-B (Recoil) | AG2-SM14-BE (Electric)
- Vanguard 400: AG2-SV14-B (Recoil) | AG2-SV14-BE (Electric)
- The High-Capacity 30-Gallon Truck-Mount Series (Suffix “-30M / -30ME”)
The commercial fleet standard. These units feature the compressor/generator platform mounted directly on top of a heavy-duty, ASME-certified 30-gallon horizontal receiver tank, providing a massive pneumatic air buffer.
- Honda GX390: AG2-SH13-30M (Recoil) | AG2-SH13-30ME (Electric)
- Kohler CH440: AG2-SK14-30M (Recoil) | AG2-SK14-30ME (Electric)
- Mi-T-M 420cc: AG2-SM14-30M (Recoil) | AG2-SM14-30ME (Electric)
- Vanguard 400: AG2-SV14-30M (Recoil) | AG2-SV14-30ME (Electric)
- Kohler KD440 Diesel: AG2-SKD9-30M (Electric Start Only) — The ultimate choice for all-diesel fleet integration, packing a commercial 9.1 HP Kohler diesel engine.
Core Engineering & Field-Proven Features
Industrial Two-Stage Pump
- 100% Cast-Iron Construction: Built with a solid cast-iron crankcase, cylinders, and deep-finned heads to dissipate extreme heat during grueling outdoor operation.
- Durability-First Components: Splash-lubricated oil bath design featuring an oil level sight glass and precision Swedish steel reed valves engineered for continuous thermal stability.
Premium Alternator Technology
- Clean, Brushless Alternator: A commercial-grade, maintenance-free alternator that maintains a total harmonic distortion (THD) of less than 6%. This ensures smooth, stable electrical current safe for diagnostic tools, laptops, and sensitive electronics.
- 100% Copper Windings: Delivers higher electrical conductivity and resists insulation breakdown caused by thermal fatigue or vibrating environments.
Smart Controls & Enclosures
- Automatic Idle Control: Features an engine governor system that automatically drops the engine down to idle when electrical and pneumatic draws cease, drastically reducing fuel costs and truck bed noise.
- Heavy-Duty Component Guards: Outfitted with a totally enclosed, heavy-gauge steel belt guard and a rugged steel control panel to shield electrical receptacles from weather and physical impact.
Technical Specification Guide
| Metric / Feature | Gasoline Models (GX390 / CH440 etc.) | Diesel Model (KD440) |
| Airflow Output | 15.7 CFM @ 175 PSI | 15.7 CFM @ 175 PSI |
| Maximum Pressure | 175 PSI | 175 PSI |
| Generator Continuous Output | 3,500 Watts | 3,000 Watts |
| Generator Maximum Output | 4,000 Watts | 3,200 Watts |
| Electrical Receptacles | (2) 120V 20A GFCI Duplex
(1) 240V 20A Twist-Lock |
(2) 120V 20A GFCI Duplex
(1) 240V 20A Twist-Lock |
Installation Note: All electric-start models require an external 12V battery, marine box, and battery cables (sold separately) to utilize the key-switch starter. Due to the weight and operational vibrations of these heavy-duty systems, they must be securely bolted to your service truck bed or shop floor using professional-grade vibration isolation pads. Always ensure adequate ventilation around the engine exhaust and cooling flywheels when designing your truck box configuration.
Reviews